Gartner shares data centre efficiency secrets

Not just load of hot air.

Power consumption at data centres is once again in the spotlight, after analyst house Gartner came up with a list of best practises in the data centre, designed to save electricity and improve cooling.

Gartner modestly claims that if companies follow all of its best practices, it could typically expect to save one million kilowatt hours. It says that in a conventional data centre, between 35 and fifty percent of the electricity consumed is for cooling compared to only 15 percent in best practise or ‘green' data centres.

"Virtually all data centres waste enormous amounts of electricity using inefficient cooling designs and systems," said Paul McGuckin, research vice president at Gartner in a statement. "Even in a small data centre, this wasted electricity amounts to more than 1 million kilowatt hours annually that could be saved with the implementation of some best practices."

Related Articles on Techworld

The main reason for the waste in conventional data centre cooling is the "unconstrained mixing of cold supply air with hot exhaust air."

"This mixing increases the load on the cooling system and energy used to provide that cooling, and reduces the efficiency of the cooling system by reducing the delta-T (the difference between the hot return temperatures and the cold supply temperature). A high delta-T is a principle in cooling," McGuckin said.

Gartner's eleven top tips for reducing power consumption are:

  • Plug holes in raised floor. This point was also raised by SunGard Availability Services last month, as apparently holes in the floor allows cold air to escape and mix with hot air. This single low-tech retrofit can save as much as 10 percent of energy used for data centre cooling, says Gartner.
  • Installing blanking panels. Data centres are full of racks, and unused rack space needs to be covered with a blanking panel so that airflow can be properly managed, for example by preventing hot air leaving equipment in one section of the rack and then entering the cold air intake for other equipment elsewhere in the rack. Gartner says when these panels are used effectively; supply air temperatures can be lowered by as much as 22 degrees Fahrenheit (or minus 5 degrees Celsius).
  • Co-ordinate CRAC units. A CRAC unit (according to Gartner) is an older Computer Room Air-conditioning Unit (CRAC). Apparently these units operate independently of each other when cooling and dehumidifying the air. Gartner suggests that if these units could be tied together with newer technologies, and their efforts co-ordinated, then the results would be a much more efficient cooling system.
  • Improve underfloor airflow. This typically affects older data centres, where the space under the raised flooring is a lot more constrained than newer builds. Many old data centres also use the underfloor spacing for running data and power cables, thereby restricting airflow. A clear out of these spaces is advised.
  • Implement hot and cold aisles. This is one of the most obvious best practises. Gartner says traditional data centres use a "classroom style" to position their racks, whereby all the intakes face in one direction. The problem with this setup is that hot air exhausted from one row, mixes with cold air being drawn into the adjacent row, thereby increasing cold-air supply temperature in uneven ways. Newer rack layout practises over the last ten years instead organise rows into hot and cold aisles, which offering much better control of air flow.
  • Install sensors. Seems obvious, but how do you tell if you have a temperature problem in a certain area of your data centre? Gartner says a minimal investment in this technology could reap big insights into data centre operations and can also provide a method for analysing the results of improvements made to the cooling systems.






Send to a friend

Email this article to a friend or colleague:

PLEASE NOTE: Your name is used only to let the recipient know who sent the story, and in case of transmission error. Both your name and the recipient's name and address will not be used for any other purpose.

Techworld White Papers

Desktop modernisation

On the one hand, there is the need to keep the existing desktop environment efficient, secure...

Download Whitepaper

Top 10 myths about virtualising business-critical applications

Even though virtualization has brought positive change to enterprise IT over the last decade,...

Download Whitepaper

Aligning CFO and CIO priorities

Forward-thinking organisations are viewing cloud computing as an investment in business...

Download Whitepaper

The new corporate network

Businesses can’t afford to have employee productivity suffer because they cannot use their...

Download Whitepaper

Techworld UK - Technology - Business

Techworld Mobile Site

Access Techworld's content on the move

Get the latest news, product reviews and downloads on your mobile device with Techworld's mobile site.

Find out more...
LogMeIn Rescue

Accelerate Your IT Efficiency

View the latest capacity management resources including whitepapers, videos and news.

Find out more...

Site Map

* *